certifiering & produkt standard
|
produkt standard
|
EN 60898
|
|
|
|
|
kompatibilitet
|
comb busbar distribution block compatibility
|
Nej
|
|
|
produkt kompatibilitet
|
tillbehör C60
|
|
|
|
|
anslutningar
|
connections - terminals
|
tunnelanslutningar flexibel wire(s) 16 mm² max
|
|
|
|
tunnelanslutningar stela skenor wire(s) 25 mm² max
|
|
|
elektrisk
|
|
|
|
[In] rated current
|
10 A at 40 °C
|
|
|
|
|
|
|
|
|
|
|
|
|
magnetic tripping limit
|
10...14 x In
|
|
|
Brytförmåga
|
6000 A Icn conforming to EN 60898 - 230/400 V AC 50/60 Hz
|
|
|
|
20 kA Icu conforming to EN/IEC 60947-2 - 130 V AC 50/60 Hz
|
|
|
|
10 kA Icu conforming to EN/IEC 60947-2 - 230...240 V AC 50/60 Hz
|
|
|
|
15 kA Icu conforming to EN/IEC 60947-2 - 60 V DC 1P
|
|
|
|
3 kA Icu conforming to EN/IEC 60947-2 - 400...415 V AC 50/60 Hz
|
|
|
[Ui] rated insulation voltage
|
500 V AC 50/60 Hz conforming to EN/IEC 60947-2
|
|
|
[Uimp] rated impulse withstand voltage
|
6 kV conforming to EN/IEC 60947-2
|
|
|
miljö
|
tropicalisation
|
2 conforming to IEC 60068-1
|
|
|
|
|
operating altitude
|
2000 m
|
|
|
temperaturområde
|
-25...60 °C
|
|
|
ambient air temperature for storage
|
-40...70 °C
|
|
|
funktion
|
limitation class
|
3 conforming to EN/IEC 60947-2
|
|
|
contact position indicator
|
ja
|
|
|
|
|
indikeringslampa
|
TILL/FRÅN indikering
|
|
|
installation
|
|
installation
|
35 mm symmetrical DIN rail
|
|
|
prestanda
|
[Ics] rated service breaking capacity
|
15 kA conforming to EN/IEC 60947-2 - 130 V AC 50/60 Hz
|
|
|
|
7.5 kA conforming to EN/IEC 60947-2 - 230...240 V AC 50/60 Hz
|
|
|
|
2.25 kA conforming to EN/IEC 60947-2 - 400...415 V AC 50/60 Hz
|
|
|
|
6000 A conforming to EN 60898 - 230/400 V AC 50/60 Hz
|
|
|
Mekanisk livslängd
|
20000 cycles
|
|
|
fysiska egenskaper
|
|
|
|
|
|
|
|
|
|
tightening torque
|
2 N.m upside effektkrets
|
|
|
|
|
artikel nummer
|
|
|
|
|
|
Utlösarteknik
|
termisk-magnetisk
|
|
|
suitability for isolation
|
ja conforming to IEC 60947-2
|
|
|
användning
|
Brytarapplikation
|
distribution
|
|