56173
RH99M 220 - 240 V AC
RH99M 220 - 240 V AC
anslutningar
auxiliary connection terminal hjälpspänningsaggregat: Plintrad 0.2...2.5 mm² (AWG: 24...12) för flexibel
hjälpspänningsaggregat: Plintrad 0.2...2.5 mm² (AWG: 24...12) för stela skenor
hjälpspänningsaggregat: Plintrad 0.25...2.5 mm² (AWG: 24...12) för flexibel
fel: skruvplint 0.2...2.5 mm² (AWG: 24...12) för flexibel
fel: skruvplint 0.2...4 mm² (AWG: 24...12) för stela skenor
fault: screw terminal 0.25...2.5 mm² (AWG: 24...12) for flexible
relay test and fault reset: skruvplint 0.14...1 mm² (AWG: 26...16) för flexibel
relay test and fault reset: screw terminal 0.14...1.5 mm² (AWG: 26...16) for rigid
relay test and fault reset: screw terminal 0.25...0.5 mm² (AWG: 26...16) for flexible
Sensor: skruvplint 0.14...1 mm² (AWG: 26...16) för flexibel
Sensor: skruvplint 0.14...1.5 mm² (AWG: 26...16) för stela skenor
sensor: screw terminal 0.25...0.5 mm² (AWG: 26...16) for flexible
voltage presence: skruvplint 0.2...2.5 mm² (AWG: 24...12) för flexibel
voltage presence: screw terminal 0.2...4 mm² (AWG: 24...12) for rigid
voltage presence: screw terminal 0.25...2.5 mm² (AWG: 24...12) for flexible
wire stripping length auxiliary power supply: 7 mm top
fel: 8 mm botten
relay test and fault reset: 5 mm bottom
Sensor: 5 mm topp
voltage presence: 8 mm bottom

elektrisk
Ue 220...240 V AC 50/60 Hz
220...240 V AC 400 Hz
fault current detection threshold 80...100 % of IDn
[Uimp] rated impulse withstand voltage 8 kV
minimum last 10 mA at 12 V
signalling output current 8 A
overvoltage category IV
power consumption 4 VA
power consumption 4 W

miljö
class of protection against electric shock klass II
immunity to microbreaks <= 60 ms
electromagnetic compatibility conducted and radiated emissions: B conforming to CISPR 11
conducted radio-frequency immunity test: 3 conforming to IEC 61000-4-6
electrostatic discharge immunity test: 4 conforming to IEC 61000-4-2
high-energy conducted susceptibility: 4 conforming to IEC 61000-4-5
low-energy conducted susceptibility: 4 conforming to IEC 61000-4-4
radiated susceptibility: 3 conforming to IEC 61000-4-3
climatic withstand heat loss: 4.45 MJ
pollution degree: 3
temperaturområde -35...70 °C
ambient air temperature for storage -55...85 °C

funktion
residual earth-leakage sensitity adjustment type Justerbar 9
residual earth-leakage time delay adjustment type momentan 0,03 A
9 justerbara inställningar 0.03...30 A 0...4.5 s
test funktion lokal
fjärrtest
tamperproof of settings skyddad av plomberbart täcklock

installation
installation DIN skena

prestanda
alarm current detection range 80...100 %

fysiska egenskaper
9mm modul 6
höjd 97 mm
bredd 54 mm
djup 74 mm
vikt 0.3 kg
mechanical robustness fire resistance conforming to IEC 60695-2-1
IK protection 2 joules: IK07 conforming to EN 50102
IP protection: IP20 conforming to IEC 60529
IP protection: IP30 conforming to IEC 60529
IP protection: IP40 conforming to IEC 60529
vibrations 13.2...100 Hz: 0.7 g
vibrations 2...13.2 Hz: +/- 1 mm
tightening torque hjälpspänningsaggregat: 0.6 N.m topp
fel: 0.6 N.m botten
relay test and fault reset: 0.25 N.m botten
sensor: 0.25 N.m top
voltage presence: 0.6 N.m botten

artikel nummer
apparatserie Vigirex
Enhets korta namn RH99M
jordfelsbrytarklass class A si
klass AC
monitoring electronics (continuous)
kraft matning (continuous)
relay/sensor link (continuous)

användning
relay application residual current protection relay
earthing system IT
TN-S
TT